10-443 |
GJ1 Circuit Breaker Panels and Circuit Breakers |
|
111-3764-00 |
2 positions (100 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over current operation, E/W LED; 3 rack spaces,
typically used as a power distribution panel. (Includes breaker) |
|
111-3764-10 |
2 positions (100 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over current operation, E/W shunt and LED; 3 rack
spaces, typically used as a power distribution panel. (Includes breaker) |
|
111-3764-01 |
2 positions (150 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over current operation, E/W LED; 3 rack spaces,
typically used as a power distribution panel. (Includes breaker) |
|
111-3764-11 |
2 positions (150 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over correct operation, E/W shunt and LED; 3 rack
spaces, typically used as a power distribution panel. (Includes breaker) |
|
111-3764-02 |
2 positions (175 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over correct operation, E/W LED; 3 rack spaces,
typically used as a power distribution panel. (Includes breaker) |
|
111-3764-12 |
2 positions (175 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over correct operation, E/W shunt and LED; 3 rack
spaces, typically used as a power distribution panel. (Includes breaker) |
|
111-3764-03 |
2 positions (225 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over correct operation, E/W LED; 3 rack spaces,
typically used as a power distribution panel. (Includes breaker) |
|
111-3764-13 |
2 positions (225 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over correct operation, E/W shunt and LED; 3 rack
spaces, typically used as a power distribution panel. (Includes breaker) |
|
111-3764-04 |
2 positions (250 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over correct operation, E/W LED; 3 rack spaces,
typically used as a power distribution panel. (Includes breaker) |
|
111-3764-14 |
2 positions (250 amps) GJ1 circuit breaker panel, with alarm switch
that switches only during over correct operation, E/W shunt and LED; 3
rack spaces, typically used as a power distribution panel. (Includes
breaker) |
|
111-3763-00 |
1 position (400 amps) GJ1 circuit breaker panel, with alarm switch that
switches only during over correct operation, E/W LED; 3 rack spaces,
typically used as a power distribution panel. (Includes breaker) |
|
111-3763-01 |
1 position (400 amps) GJ1 circuit breaker panel, "auxiliary switch"
interlock with main contact on/off operation, E/W LED;3 rack spaces,
typically used as a battery disconnect panel. (Includes breaker) |
|
|
|
|
10-443 |
GJ1 Circuit Breaker Panels and Circuit Breakers - (Con't) |
|
111-3763-10 |
1 position (400 amps) GJ1 circuit breaker panel, with alarm switch E/W
shunt and LED; 3 rack spaces, typically used as a power distribution
panel. (Includes breaker) |
|
111-3763-11 |
1 position (400 amps) GJ1 circuit breaker panel, "auxiliary switch"
interlocks with main contact on/off operation, E/W shunt and LED;3 rack
spaces, typically used as a battery disconnect panel. (Includes
breaker) |
|
111-3762-00 |
1 position (600 amps) GJ1 circuit breaker panel, with alarm switch, E/W
LED; 3 rack spaces, typically used as a power distribution panel.
(Includes breaker) |
|
111-3762-01 |
1 position (600 amps) GJ1 circuit breaker panel, "auxiliary switch"
interlocks with main contact on/off operation, E/W LED; 3 rack spaces,
typically used as a battery disconnect panel. (Includes breaker) |
|
111-3762-10 |
1 position (600 amps) GJ1 circuit breaker panel, with alarm switch, E/W
shunt and LED; 3 rack spaces, typically used as a power distribution
panel. (Includes breaker) |
|
111-3762-11 |
1 position (600 amps) GJ1 circuit breaker panel, "auxiliary switch"
interlocks with main contact on/off operation, E/W shunt and LED; 3
rack spaces, typically used as a battery disconnect panel. (Includes
breaker) |
|
|
|
|
|
Optional Relay Contacts |
|
385-5154-00 |
Alarm/LED assembly, replaces standard FA/LED assembly on distribution
panels when form-C relay contacts are required |