10-960 |
The AGM 600 Power Plant (PDS 4200) |
|
|
PDS 4200 is a -48 Vdc, 600 ADC integrated system which features modular
rectifiers, |
|
|
distribution, monitoring and optional low-voltage disconnect. Can be
E/W with up |
|
|
to twelve HFM48BC50 rectifiers or six HFM48AC30 rectifiers. |
|
|
|
|
|
Basic Plant Configurations |
|
110-4200L-1A |
AGM 600 w/o LVD 23" relay rack mount, E/W one HFM48BC50 Rectifier shelf
and 24 circuit breaker position (Relay rack, rectifiers and circuit
breakers NOT included) |
|
110-4200L-2A |
AGM 600 with LVD 23" relay rack mount, E/W one HFM48BC50 Rectifier shelf
and 24 circuit breaker position (Relay rack, rectifiers and circuit
breakers NOT included) |
|
110-4200L-3A |
AGM 600 w/o LVD 23" relay rack mount, E/W one HFM48AC30 rectifier shelf
and 24 circuit breaker position (Relay rack, rectifiers and circuit
breakers NOT included) |
|
110-4200L-4A |
AGM 600 with LVD 23" relay rack mount, E/W one HFM48AC30 rectifier shelf
and 24 circuit breaker position (Relay rack, rectifiers and circuit
breakers NOT included) |
|
|
|
|
|
Modular Rectifier Options |
|
100-7500-00 |
HFM48BC50 rectifier 48V, 50A (208/240 vac Only) |
|
100-7530-48 |
HFM48AC30 rectifier 48V, 30A (120/208/240 VAC) |
|
|
|
|
|
Optional Equipment |
|
111-3840-01 |
AGM 600 Distribution Expansion cabinet E/W: additional twenty-four
-48VDC circuit breaker positions(circuit breakers NOT included) |
|
111-3840-03 |
AGM 600 Distribution Expansion cabinet E/W: additional forty-eight
-48VDC circuit breaker positions(circuit breakers NOT included) |
|
385-5684-00 |
AGM 600 additional 21 circuit breaker positions - For a total of 45
positions internal to the AGM 600. (Circuit breakers NOT included) |
|
385-5685-00 |
HFM48BC50 Rectifier Shelf 400 AMP Upgrade Kit - (1 additional shelf) |
|
|
(Used with 110-4200L-1A AND 110-4200L-2A systems to expand plant to 400
AMP capacity - Rectifier NOT included) |
|
|
|
|
385-5686-00 |
HFM48BC50 Rectifier Shelf 600 AMP Upgrade Kit - (2 additional shelves) |
|
|
(Used with 110-4200L-1A AND 110-4200L-2A systems to expand plant to 600
AMP capacity - Rectifier NOT included) |
|
|
|
|
385-5687-00 |
AGM 600 Battery Temperature Compensation Option, (1 ambient and 3
battery sensors) |
|
|
(System using HFM48BC50 or HFM48AC30 rectifiers) |
|
|
|
|
|
Optional Equipment |
|
385-5696-00 |
AGM 600 Front Access AC Wiring - 180 AMP Option |
|
|
(System using HFM48AC30 rectifiers) |
|
|
|
|
385-5697-00 |
AGM 600 Front Access AC Wiring - 360 AMP Option |
|
|
(System using HFM48AC30 rectifiers) |
|
|
|
|
385-5688-00 |
AGM 600 Front Access AC Wiring - 200 AMP Option |
|
|
(System using HFM48BC50 rectifiers) |
|
|
|
|
385-5689-00 |
AGM 600 Front Access AC Wiring - 400 AMP Option |
|
|
(System using HFM48BC50 rectifiers) |
|
|
|
|
385-5690-00 |
AGM 600 Front Access AC Wiring - 600 AMP Option |
|
|
(System using HFM48BC50 rectifiers) |
|
|
|
|
385-5778-00 |
Upgrade kit for External Distribution |
|
|
|
|
|
Circuit Breakers |
|
271-0160-40 |
AM1 Snap In Type, 1 AMP Circuit Breaker - 1 breaker position |
|
271-0160-50 |
AM1 Snap In Type, 3 AMP Circuit Breaker - 1 breaker position |
|
271-0161-00 |
AM1 Snap In Type, 5 AMP Circuit Breaker - 1 breaker position |
|
271-0162-00 |
AM1 Snap In Type, 10 AMP Circuit Breaker - 1 breaker position |
|
271-0162-50 |
AM1 Snap In Type, 15 AMP Circuit Breaker - 1 breaker position |
|
271-0163-00 |
AM1 Snap In Type, 20 AMP Circuit Breaker - 1 breaker position |
|
271-0160-00 |
AM1 Snap In Type, 25 AMP Circuit Breaker - 1 breaker position |
|
271-0164-00 |
AM1 Snap In Type, 30 AMP Circuit Breaker - 1 breaker position |
|
271-0165-00 |
AM1 Snap In Type, 40 AMP Circuit Breaker - 1 breaker position |
|
271-0166-00 |
AM1 Snap In Type, 50 AMP Circuit Breaker - 1 breaker position |
|
274-3796-60 |
AM1 Snap In Type, 60 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-70 |
AM1 Snap In Type, 70 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-80 |
AM1 Snap In Type, 80 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-90 |
AM1 Snap In Type, 90 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-100 |
AM1 Snap In Type, 100 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-125 |
AM1 Snap In Type, 125 AMP Circuit Breaker - 3 breaker positions, E/W
busbar adapter |