10-958 |
The ACM 600 Power Plant (PDS 4100) |
|
|
PDS 4100 is a +24 Vdc, 600 ADC integrated system which features modular
Rectifiers, distribution, |
|
|
monitoring and optional low-voltage disconnect. Can be E/W up to four
HFM24BC150 rectifiers or |
|
|
six HFM24AC60 rectifiers |
|
|
|
|
|
Basic Plant Configurations |
|
110-4100L-1A |
ACM 600 w/o LVD, 23" relay rack mount, E/W one HFM24BC150 rectifier
shelf and 24 circuit breaker position (Relay rack, rectifiers, and
circuit breakers NOT included) |
|
110-4100L-2A |
ACM 600 with LVD, 23" relay rack mount, E/W one HFM24BC150 rectifier
shelf and 24 circuit breaker position (Relay rack, rectifiers, and
circuit breakers NOT included) |
|
110-4100L-3A |
ACM 600 w/o LVD, 23" relay rack mount, E/W one HFM24AC60 rectifier shelf
and 24 circuit breaker position (Relay rack, rectifiers, and circuit
breakers NOT included) |
|
110-4100L-4A |
ACM 600 with LVD, 23" relay rack mount, E/W one HFM24AC60 rectifier
shelf and 24 circuit breaker position (Relay rack, rectifiers, and
circuit breakers NOT included) |
|
|
|
|
|
Modular Rectifier Options |
|
100-7520-24 |
HFM24BC150 rectifier 24V, 150A (208/240 VAC Only) |
|
100-7560-24 |
HFM24AC60 rectifier 24V, 60A (115/208/220/240) |
|
|
|
|
|
Optional Equipment |
|
385-5674-00 |
ACM 600 DC/DC Converter Enclosure |
|
|
Holds up to 5 +24VDC to -48VDC, 3 AMP |
|
|
|
|
|
Converter Modules(106-4080-00) Converters NOT included |
|
385-5692-00 |
GMT Extended Distribution, -48V, 10 positions |
|
106-4080-00 |
+24 Vdc to -48 Vdc, 3 A DC to DC Converter Module with fan |
|
111-3840-00 |
ACM 600 Distribution Expansion cabinet E/W: additional twenty-four
+24VDC circuit breaker positions(circuit breakers NOT included) |
|
111-3840-02 |
ACM 600 Distribution Expansion cabinet E/W: additional forty-eight
+24VDC circuit breaker positions(circuit breakers NOT included) |
|
|
|
|
|
Optional Equipment |
|
111-3840-04 |
ACM 600 Distribution Expansion cabinet E/W twenty-four 24 +24VDC circuit
breaker positions and additional twenty-four -48VDC circuit breaker
positions (circuit breakers NOT included) |
|
385-5675-00 |
ACM Battery Temperature Compensation Option- includes 1 ambient and 3
battery sensors |
|
|
|
|
|
(System using HFM24BC150 or HFM24AC60 Rectifiers) |
|
385-5676-00 |
ACM 600 Front Access AC Wiring |
|
|
|
|
|
(System using HFM24BC150 rectifiers) |
|
385-5778-00 |
Upgrade kit for External Distribution |
|
|
|
|
|
Circuit Breakers |
|
271-0160-40 |
AM1 Snap In Type, 1 AMP Circuit Breaker - 1 breaker position |
|
271-0160-50 |
AM1 Snap In Type, 3 AMP Circuit Breaker - 1 breaker position |
|
271-0161-00 |
AM1 Snap In Type, 5 AMP Circuit Breaker - 1 breaker position |
|
271-0162-00 |
AM1 Snap In Type, 10 AMP Circuit Breaker - 1 breaker position |
|
271-0162-50 |
AM1 Snap In Type, 15 AMP Circuit Breaker - 1 breaker position |
|
271-0163-00 |
AM1 Snap In Type, 20 AMP Circuit Breaker - 1 breaker position |
|
271-0160-00 |
AM1 Snap In Type, 25 AMP Circuit Breaker - 1 breaker position |
|
271-0164-00 |
AM1 Snap In Type, 30 AMP Circuit Breaker - 1 breaker position |
|
271-0165-00 |
AM1 Snap In Type, 40 AMP Circuit Breaker - 1 breaker position |
|
271-0166-00 |
AM1 Snap In Type, 50 AMP Circuit Breaker - 1 breaker position |
|
274-3796-60 |
AM1 Snap In Type, 60 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-70 |
AM1 Snap In Type, 70 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-80 |
AM1 Snap In Type, 80 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-90 |
AM1 Snap In Type, 90 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-100 |
AM1 Snap In Type, 100 AMP Circuit Breaker - 2 breaker positions, E/W
busbar adapter |
|
274-3796-125 |
AM1 Snap In Type, 125 AMP Circuit Breaker - 3 breaker positions, E/W
busbar adapter |
|
|
|
|
|
GMT Fuses : .18 - 10 AMPS |
|
276-0002-00 |
GMT Fuse, dummy |
|
280-0720-00 |
GMT Fuse 0.18 ampere |
|
280-0730-00 |
GMT Fuse 0.25 ampere |
|
280-0700-00 |
GMT Fuse 0.5 ampere |
|
280-0705-00 |
GMT Fuse 0.75 ampere |
|
280-0710-00 |
GMT Fuse 1 ampere |
|
280-0715-00 |
GMT Fuse 1.33 ampere |
|
280-0735-00 |
GMT Fuse 2 ampere |
|
280-0760-00 |
GMT Fuse 3 ampere |
|
280-0740-00 |
GMT Fuse 5 ampere |
|
280-0750-00 |
GMT Fuse 7.5 ampere |
|
280-0770-00 |
GMT Fuse 10 ampere |