10-945 |
The ACM 1800 Power Plant (PDS 4191) |
|
|
PDS 4191 is a +24 Vdc, 150 to 1,800 ADC system which features modular
Rectifiers, distribution, |
|
|
and a digital meter and alarm panel. Equipped with low-voltage
disconnect. |
|
|
|
|
|
Basic Plant Configurations for 150-ampere Rectifiers |
|
110-4191L-1A |
PDS 4191, List 1 includes 23" X 7' relay rack, front-accessible, +24Vdc
distribution bay mounted in a 23" by 7' relay rack. E/W battery charge
bus, ground charge bus, ground return bus, two rectifier shelves,
digital meter, and 36 standard breaker posit |
|
110-4191L-2A |
PDS 4191, List 2 includes 23" X 7' relay rack, front-accessible, +24Vdc
distribution bay mounted in a 23" by 7' relay rack. E/W battery charge
bus, ground charge bus, ground return bus, three rectifier shelves,
digital meter, and 36 standard breaker pos |
|
110-4191L-3A |
PDS 4191, List 3 includes 23" X 7' relay rack, front-accessible, +24Vdc
distribution bay mounted in a 23" by 7' relay rack. E/W battery charge
bus, ground charge bus, ground return bus, one rectifier shelf, digital
meter, and 36 standard breaker positio |
|
|
|
|
|
Distribution Options |
|
385-4191-00 |
Hardware and wiring for Group C with 18 additional 5 to 100 ampere type
AM1 +24V breaker positions. |
|
385-4191-01 |
Hardware and wiring for Group D with 18 additional 5 to 100 ampere type
AM1 +24V breaker positions. |
|
385-4191-02 |
Hardware and wiring for Group E with 10 additional 5 to 60 ampere type
AM1 +24V breaker positions. (Rated at 80A Maximum) |
|
385-4191-03 |
Hardware and wiring for Group E with 10 each 0.18 to 10 ampere GMT +24V
or -48V fuse positions. (Rated for 30 Amps max.) |
|
385-4191-04 |
Hardware and wiring for Group C with 4 each 150 to 400 ampere type GJ1
+24V breaker positions. |
|
385-4191-05 |
Hardware and wiring for Group D with 4 each 150 to 400 ampere type GJ1
+24V breaker positions. |
|
385-4191-06 |
Hardware and wiring for Group F with 4 each 150 to 400 ampere type GJ1
+24V breaker positions. |
|
385-4191-07 |
Hardware and wiring for Group E with 10 additional 5 to 60 ampere type
AM1 -48V breaker positions. (Rated at 80A Maximum) |
|
385-4191-15 |
Tempertaure Compensation Option : 1 Ambient and 3 remote sensing probes |
|
385-4191-20 |
Hardware and wiring for Group E or F with 40 each 0.18 to 10 ampere GMT
+24V or -48V fuse positions. (Rated for 50 Amps max.) |
|
|
|
|
|
Modular Rectifiers |
|
100-7520-24 |
HFM24BC150 rectifier 24V, 150A (208/240 VAC Only) |
|
|
|
|
|
Field Upgrade Kits |
|
385-4191-11 |
Upgrade kit to 1200A for use with List-3 plant to add shelf in the
second position |
|
385-4191-10 |
Upgrade kit to 1800A for use with List-1 plant to add shelf in the
third position |
|
|
|
|
|
Modular Converters |
|
385-4191-25 |
Modular 24 to 48 Vdc converter, 20 amperes, includes one 60 Amp breaker
for converter input |
|
385-4191-24 |
Modular 24 to 48 Vdc converter, 10 amperes, includes one 40 Amp breaker
for converter input |
|
385-4191-22 |
80 AMP Shelf for modular 20 Amp DC to DC converters |
|
385-5668-00 |
40 AMP Shelf for modular 10 Amp DC to DC converters |
|
|
|
|
|
Plug-In Bullet Breakers : 100 - 450 AMPS |
|
274-3830-05 |
AM1 Circuit Breaker Kit 5 ampere, 1 breaker position |
|
274-3830-10 |
AM1 Circuit Breaker Kit 10 ampere, 1 breaker position |
|
274-3830-20 |
AM1 Circuit Breaker Kit 20 ampere, 1 breaker position |
|
274-3830-30 |
AM1 Circuit Breaker Kit 30 ampere, 1 breaker position |
|
274-3830-40 |
AM1 Circuit Breaker Kit 40 ampere, 1 breaker position |
|
274-3830-50 |
AM1 Circuit Breaker Kit 50 ampere, 1 breaker position |
|
274-3830-60 |
AM1 Circuit Breaker Kit 60 ampere, 1 breaker position |
|
274-3830-70 |
AM1 Circuit Breaker Kit 70 ampere, 2 breaker positions |
|
274-3830-80 |
AM1 Circuit Breaker Kit 80 ampere, 2 breaker positions |
|
274-3830-90 |
AM1 Circuit Breaker Kit 100 ampere, 2 breaker positions |
|
274-3830-100 |
AM1 Circuit Breaker Kit 125 ampere, 2 breaker positions |
|
|
|
|
|
Bolt-In Breakers : 5 - 225 AMPS |
|
274-3833-100 |
GJ1 Circuit Breaker Kit 100 ampere, 1 breaker positions |
|
274-3833-125 |
GJ1 Circuit Breaker Kit 125 ampere, 1 breaker positions |
|
274-3833-150 |
GJ1 Circuit Breaker Kit 150 ampere, 1 breaker positions |
|
274-3833-175 |
GJ1 Circuit Breaker Kit 175 ampere, 1 breaker positions |
|
274-3833-225 |
GJ1 Circuit Breaker Kit 225 ampere, 1 breaker positions |
|
274-3833-250 |
GJ1 Circuit Breaker Kit 250 ampere, 1 breaker positions |
|
274-3833-300 |
GJ1 Circuit Breaker Kit 300 ampere, 2 breaker positions |
|
274-3833-350 |
GJ1 Circuit Breaker Kit 350 ampere, 2 breaker positions |
|
274-3833-400 |
GJ1 Circuit Breaker Kit 400 ampere, 2 breaker positions |
|
274-3833-450 |
GJ1 Circuit Breaker Kit 450 ampere, 2 breaker positions |
|
|
|
|
|
GMT Fuses : .18 - 10 AMPS |
|
276-0002-00 |
GMT Fuse, dummy |
|
280-0720-00 |
GMT Fuse 0.18 ampere |
|
280-0730-00 |
GMT Fuse 0.25 ampere |
|
280-0700-00 |
GMT Fuse 0.5 ampere |
|
280-0705-00 |
GMT Fuse 0.75 ampere |
|
280-0710-00 |
GMT Fuse 1 ampere |
|
280-0715-00 |
GMT Fuse 1.33 ampere |
|
280-0735-00 |
GMT Fuse 2 ampere |
|
280-0760-00 |
GMT Fuse 3 ampere |
|
280-0740-00 |
GMT Fuse 5 ampere |
|
280-0750-00 |
GMT Fuse 7.5 ampere |
|
280-0770-00 |
GMT Fuse 10 ampere |